998 resultados para epidural space


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background. Thoracic epidural catheters provide the best quality postoperative pain relief for major abdominal and thoracic surgical procedures, but placement is one of the most challenging procedures in the repertoire of an anesthesiologist. Most patients presenting for a procedure that would benefit from a thoracic epidural catheter have already had high resolution imaging that may be useful to assist placement of a catheter. Methods. This retrospective study used data from 168 patients to examine the association and predictive power of epidural-skin distance (ESD) on computed tomography (CT) to determine loss of resistance depth acquired during epidural placement. Additionally, the ability of anesthesiologists to measure this distance was compared to a radiologist, who specializes in spine imaging. Results. There was a strong association between CT measurement and loss of resistance depth (P < 0.0001); the presence of morbid obesity (BMI > 35) changed this relationship (P = 0.007). The ability of anesthesiologists to make CT measurements was similar to a gold standard radiologist (all individual ICCs > 0.9). Conclusions. Overall, this study supports the examination of a recent CT scan to aid in the placement of a thoracic epidural catheter. Making use of these scans may lead to faster epidural placements, fewer accidental dural punctures, and better epidural blockade.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BackgroundThe success of epidural anaesthesia depends on correct identification of the epidural space. For several decades, the decision of whether to use air or physiological saline during the loss of resistance technique for identification of the epidural space has been governed by the personal experience of the anaesthesiologist. Epidural block remains one of the main regional anaesthesia techniques. It is used for surgical anaesthesia, obstetrical analgesia, postoperative analgesia and treatment of chronic pain and as a complement to general anaesthesia. The sensation felt by the anaesthesiologist from the syringe plunger with loss of resistance is different when air is compared with saline (fluid). Frequently fluid allows a rapid change from resistance to non-resistance and increased movement of the plunger. However, the ideal technique for identification of the epidural space remains unclear.ObjectivesTo evaluate the efficacy and safety of both air and saline in the loss of resistance technique for identification of the epidural space.To evaluate complications related to the air or saline injected.Search methodsWe searched the Cochrane Central Register of Controlled Trials (CENTRAL) (2013, Issue 9), MEDLINE, EMBASE and the Latin American and Caribbean Health Science Information Database (LILACS) (from inception to September 2013). We applied no language restrictions. The date of the most recent search was 7 September 2013.Selection criteriaWe included randomized controlled trials (RCTs) and quasi-randomized controlled trials (quasi-RCTs) on air and saline in the loss of resistance technique for identification of the epidural space.Data collection and analysisTwo review authors independently assessed trial quality and extracted data.Main resultsWe included in the review seven studies with a total of 852 participants. The methodological quality of the included studies was generally ranked as showing low risk of bias inmost domains, with the exception of one study, which did not mask participants. We were able to include data from 838 participants in the meta-analysis. We found no statistically significant differences between participants receiving air and those given saline in any of the outcomes evaluated: inability to locate the epidural space (three trials, 619 participants) (risk ratio (RR) 0.88, 95% confidence interval (CI) 0.33 to 2.31, low-quality evidence); accidental intravascular catheter placement (two trials, 223 participants) (RR 0.90, 95% CI 0.33 to 2.45, low-quality evidence); accidental subarachnoid catheter placement (four trials, 682 participants) (RR 2.95, 95% CI 0.12 to 71.90, low-quality evidence); combined spinal epidural failure (two trials, 400 participants) (RR 0.98, 95% CI 0.44 to 2.18, low-quality evidence); unblocked segments (five studies, 423 participants) (RR 1.66, 95% CI 0.72 to 3.85); and pain measured by VAS (two studies, 395 participants) (mean difference (MD) -0.09, 95% CI -0.37 to 0.18). With regard to adverse effects, we found no statistically significant differences between participants receiving air and those given saline in the occurrence of paraesthesias (three trials, 572 participants) (RR 0.89, 95% CI 0.69 to 1.15); difficulty in advancing the catheter (two trials, 227 participants) (RR 0.91, 95% CI 0.32 to 2.56); catheter replacement (two trials, 501 participants) (RR 0.69, 95% CI 0.26 to 1.83); and postdural puncture headache (one trial, 110 participants) (RR 0.83, 95% CI 0.12 to 5.71).Authors' conclusionsLow-quality evidence shows that results do not differ between air and saline in terms of the loss of resistance technique for identification of the epidural space and reduction of complications. Applicability might be compromised, as most of the results described in this review were obtained from parturient patients. This review underlines the need to conduct well-designed trials in this field.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND: Ritonavir inhibition of cytochrome P450 3A4 decreases the elimination clearance of fentanyl by 67%. We used a pharmacokinetic model developed from published data to simulate the effect of sample patient-controlled epidural labor analgesic regimens on plasma fentanyl concentrations in the absence and presence of ritonavir-induced cytochrome P450 3A4 inhibition. METHODS: Fentanyl absorption from the epidural space was modeled using tanks-in-series delay elements. Systemic fentanyl disposition was described using a three-compartment pharmacokinetic model. Parameters for epidural drug absorption were estimated by fitting the model to reported plasma fentanyl concentrations measured after epidural administration. The validity of the model was assessed by comparing predicted plasma concentrations after epidural administration to published data. The effect of ritonavir was modeled as a 67% decrease in fentanyl elimination clearance. Plasma fentanyl concentrations were simulated for six sample patient-controlled epidural labor analgesic regimens over 24 h using ritonavir and control models. Simulated data were analyzed to determine if plasma fentanyl concentrations producing a 50% decrease in minute ventilation (6.1 ng/mL) were achieved. RESULTS: Simulated plasma fentanyl concentrations in the ritonavir group were higher than those in the control group for all sample labor analgesic regimens. Maximum plasma fentanyl concentrations were 1.8 ng/mL and 3.4 ng/mL for the normal and ritonavir simulations, respectively, and did not reach concentrations associated with 50% decrease in minute ventilation. CONCLUSION: Our model predicts that even with maximal clinical dosing regimens of epidural fentanyl over 24 h, ritonavir-induced cytochrome P450 3A4 inhibition is unlikely to produce plasma fentanyl concentrations associated with a decrease in minute ventilation.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Buprenorphine plasma concentrations were measured after administering buprenorphine (20 mu g/kg) into the lumbosacral epidural space of conscious cats chronically instrumented with an epidural catheter. Blood was collected from a jugular vein before injection and 15, 30, 45 and 60 min and 2, 3, 4, 5, 6, 8, 12 and 24 h after administration. Plasma buprenorphine concentrations were measured using ELISA. Background concentration (before injection) was 1.27 +/- 0.27 ng/mL (mean +/- SD). Including background concentration, the mean peak plasma concentration was obtained 15 min after injection (5.82 +/- 3.75 ng/mL), and ranged from 3.79 to 2.20 ng/mL (30 min-3 h), remaining between 1.93 and 1.77 ng/mL (412 h), and declined to 1.40 +/- 0.62 ng/mL at 24 h. Elimination half-life was 58.8 +/- 40.2 min and clearance 56.7 +/- 21.5 mL/min. Results indicate early rapid systemic uptake of buprenorphine from epidural administration with plasma concentrations similar to using buccal or IM routes by 15 min postinjection. (C) 2010 Elsevier Ltd. All rights reserved.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

An epidural puncture was performed using the lumbosacral approach in 18 dogs, and the lack of resistance to an injection of saline was used to determine that the needle was positioned correctly. The dogs' arterial blood pressure and epidural pressure were recorded. They were randomly assigned to two groups: in one group an injection of a mixture of local anaesthetic agents was made slowly over 90 seconds and in the other it was made over 30 seconds. After 10 minutes contrast radiography was used to confirm the correct placement of the needle. The mean (sd) initial pressure in the epidural space was 0.1 (0.7) kPa. After the injection the mean maximum epidural pressure in the group injected slowly was 5.5 (2.1) kPa and in the group injected more quickly it was 6.0 (1.9) kPa. At the end of the period of measurement, the epidural pressure in the slow group was 0.8 (0.5) kPa and in the rapid group it was 0.7 (0.5) kPa. Waves synchronous with the arterial pulse wave were observed in 15 of the dogs before the epidural injection, and in all the dogs after the epidural injection.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND Little is known about the pathologic changes in the epidural space after intervertebral disk (IVD) extrusion in the dog. OBJECTIVES To analyze the pathology of the epidural inflammatory response, and to search for correlations between this process and clinical findings. METHODS Clinical data from 105 chondrodystrophic (CD) and nonchondrodystrophic (NCD) dogs with IVD extrusion were recorded. Epidural material from these dogs was examined histopathologically and immunohistochemically. Using statistical analysis, we searched for correlations between severity of epidural inflammation and various clinical and pathologic variables. RESULTS Most dogs exhibited an epidural inflammatory response, ranging from acute invasion of neutrophils to formation of chronic granulation tissue. The mononuclear inflammatory infiltrates consisted mostly of monocytes and macrophages and only few T and B cells. Surprisingly, chronic inflammatory patterns also were found in animals with an acute clinical history. Severity of the epidural inflammation correlated with degree of the epidural hemorrhage and nucleus pulposus calcification (P = .003 and .040), but not with age, chondrodystrophic phenotype, neurologic grade, back pain, pretreatment, or duration. The degree of inflammation was statistically (P = .021) inversely correlated with the ability to regain ambulation. CONCLUSION AND CLINICAL IMPORTANCE Epidural inflammation occurs in the majority of dogs with IVD extrusion and may develop long before the onset of clinical signs. Presence of calcified IVD material and hemorrhage in the epidural space may be the triggers of this lesion rather than an adaptive immune response to the nucleus pulposus as suggested in previous studies. Because epidural inflammation may affect outcome, further research is warranted.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A two-year-old female Lucerne Hound was presented with a one-week history of signs of progressive neck pain, inappetence, apathy, and an elevated rectal temperature. Findings of magnetic resonance imaging (MRI) were consistent with a foreign body abscess in the epidural space at the level of the first and second cervical vertebrae. A left-sided dorso-lateral atlantoaxial approach was performed, revealing an epidural abscess containing a grass awn. The clinical signs resolved within three days of surgery and the dog made a full recovery. This case report shows that grass awns can migrate to the atlantoaxial region in dogs and MRI findings lead to a suspicion of caudo-cranial migration within the spinal canal.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The use of pressure waves to confirm the correct position of the epidural needle has been described in several domestic species and proposed as a valid alternative to standard methods, namely, control radiographic exam and fluoroscopy. The object of this retrospective clinical study was to evaluate the sensitivity of the epidural pressure waves as a test to verify the correct needle placement in the epidural space in dogs, in order to determine whether this technique could be useful not only in the clinical setting but also when certain knowledge of needle's tip position is required, for instance when performing clinical research focusing on epidural anaesthesia. Of the 54 client-owned dogs undergoing elective surgeries and enrolled in this retrospective study, only 45% showed epidural pressure waves before and after epidural injection. Twenty-six percent of the animals showed epidural pressure waves only after the injection, whereas 29% of the dogs showed epidural pressure waves neither before nor after injection and were defined as false negatives. Our results show that the epidural pressure wave technique to verify epidural needle position lacks sensitivity, resulting in many false negatives. As a consequence, the applicability of this technique is limited to situations in which precise, exact knowledge of the needle's tip position is not mandatory.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

BACKGROUND CONTEXT In canine intervertebral disc (IVD) disease, a useful animal model, only little is known about the inflammatory response in the epidural space. PURPOSE To determine messenger RNA (mRNA) expressions of selected cytokines, chemokines, and matrix metalloproteinases (MMPs) qualitatively and semiquantitatively over the course of the disease and to correlate results to neurologic status and outcome. STUDY DESIGN/SETTING Prospective study using extruded IVD material of dogs with thoracolumbar IVD extrusion. PATIENT SAMPLE Seventy affected and 13 control (24 samples) dogs. OUTCOME MEASURES Duration of neurologic signs, pretreatment, neurologic grade, severity of pain, and outcome were recorded. After diagnostic imaging, decompressive surgery was performed. METHODS Messenger RNA expressions of interleukin (IL)-1β, IL-2, IL-4, IL-6, IL-8, IL-10, tumor necrosis factor (TNF), interferon (IFN)γ, MMP-2, MMP-9, chemokine ligand (CCL)2, CCL3, and three housekeeping genes was determined in the collected epidural material by Panomics 2.0 QuantiGene Plex technology. Relative mRNA expression and fold changes were calculated. Relative mRNA expression was correlated statistically to clinical parameters. RESULTS Fold changes of TNF, IL-1β, IL-2, IL-4, IL-6, IL-10, IFNγ, and CCL3 were clearly downregulated in all stages of the disease. MMP-9 was downregulated in the acute stage and upregulated in the subacute and chronic phase. Interleukin-8 was upregulated in acute cases. MMP-2 showed mild and CCL2 strong upregulation over the whole course of the disease. In dogs with severe pain, CCL3 and IFNγ were significantly higher compared with dogs without pain (p=.017/.020). Dogs pretreated with nonsteroidal anti-inflammatory drugs revealed significantly lower mRNA expression of IL-8 (p=.017). CONCLUSIONS The high CCL2 levels and upregulated MMPs combined with downregulated T-cell cytokines and suppressed pro-inflammatory genes in extruded canine disc material indicate that the epidural reaction is dominated by infiltrating monocytes differentiating into macrophages with tissue remodeling functions. These results will help to understand the pathogenic processes representing the basis for novel therapeutic approaches. The canine IVD disease model will be rewarding in this process.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Foram realizados estudos empregando-se analgésicos por via epidural e subcutânea em cadelas de diferentes raças e idades, submetidas à castração mediante celiotomia. Vinte animais foram tranquilizados e anestesiados com tiletamina-zolazepam, e aleatoriamente distribuídos em quatro grupos (n=5), de acordo com o fármaco e a via de administração. Os do grupo morfina (GM) foram submetidos à anestesia epidural no espaço lombossacro, com morfina (0,1mg/kg) associada ao cloreto de sódio a 0,9%. Aos do grupo xilazina (GX), foram administrados xilazina (0,2mg/kg) e cloreto de sódio a 0,9%. Os do grupo meloxicam (GME) receberam 0,2mg/kg do anti-inflamatório meloxicam associado ao cloreto de sódio a 0,9%, injetado pela via subcutânea. Os do grupo-controle (CG) receberam apenas cloreto de sódio a 0,9%. O volume final para as injeções epidurais foi padronizado para 0,3mL/kg. A mensuração inicial da concentração de cortisol plasmático, do ritmo cardíaco, da frequência respiratória e os parâmetros comportamentais foram registrados imediatamente antes do procedimento cirúrgico (M1). Registros adicionais foram apresentados às 2, 6, 12 e 24 horas após o procedimento cirúrgico (M2, M3, M4 e M5, respectivamente). As variáveis comportamentais foram avaliadas por meio de sinais clínicos e seus respectivos escores. em GX foram observadas depressão respiratória, bradicardia e concentração de cortisol mais alta do que o registrado no GM. A analgesia obtida pelo meloxicam foi considerada ineficiente. É possível concluir que a morfina, via epidural, promoveu menor incidência de efeitos colaterais e melhor analgesia e bem-estar animal.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

JUSTIFICATIVA E OBJETIVOS: Não existem estudos que relatem as repercussões renais determinadas pela injeção de doses elevadas de clonidina no espaço peridural. O objetivo do estudo foi avaliar os efeitos hemodinâmicos e renais determinados pela injeção de doses elevadas de clonidina no espaço peridural do cão. MÉTODO: Vinte animais anestesiados com tiopental sódico e fentanil foram distribuídos aleatoriamente e de forma duplamente encoberta em dois grupos: Grupo 1 ou placebo (n = 10), que recebeu 0,2 mL.kg-1 de solução fisiológica, e Grupo 2 ou clonidina (n = 10), que recebeu 0,2 mL.kg-1 de uma solução contendo 50 µg.mL-1 de clonidina, no espaço peridural. Foram avaliados os seguintes parâmetros hemodinâmicos: freqüência cardíaca (FC): bat.min-1; pressão arterial média (PAM): mmHg; pressão da artéria pulmonar ocluida (PAOP): mmHg; débito cardíaco (DC): L.min-1; volume sistólico (VS): mL; também, os seguintes parâmetros da função renal foram avaliados: fluxo sangüíneo renal (FSR): mL.min-1; resistência vascular renal (RVR): mmHg.mL-1.min; volume urinário minuto (VUM): mL.min-1; depuração de creatinina (D Cr): mL.min-1; depuração de para-aminohipurato (D PAH): mL.min-1; fração de filtração (FF); depuração de sódio (D Na): mL.min-1; depuração de potássio (D K): mL.min-1; excreção fracionária de sódio (EF Na): %; excreção urinária de sódio (U NaV): µEq.min-1; excreção urinária de potássio (U K V): µEq.min-1. O experimento consistiu em três momentos de 20 minutos cada. Os dados foram coletados aos 10 minutos de cada momento e a diurese, no início e no final de cada momento. Ao término de M1, a clonidina ou a solução fisiológica foi administrada no espaço peridural. Após período de 20 minutos iniciou-se M2 e, em seguida, M3. RESULTADOS: A clonidina na dose de 10 µg.kg-1 no espaço peridural do cão promoveu alterações significativas, com diminuições da freqüência cardíaca e do débito cardíaco e aumento da relação depuração de para-aminohipurato de sódio/débito cardíaco. CONCLUSÕES: Nas condições realizadas e nas doses empregadas, pode-se concluir que a clonidina não promoveu alteração da função renal, mas diminuiu valores hemodinâmicos (freqüência e débito cardíaco).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective To assess cardiopulmonary and analgesic effects after administration of ropivacaine into the caudal epidural space of cattle.Study design Prospective, single-dose trial.Animals Eight healthy mixed breed cows aged 8 +/- 5 years and weighing 507 +/- 112 kg.Methods Caudal epidural anesthesia was produced in cows with 0.75% ropivacaine (0.11 mg kg(-1)). Onset time, duration and cranial spread of analgesia were recorded. Heart rate (HR), respiratory rate (f(R)), rectal temperature (RT), and mean arterial blood pressure (MAP) were measured prior to epidural administration (T-0) and at 15, 30, 60, 120, 180 and 240 minutes after epidural administration (T-15, T-30, T-60, T-120, T-180 and T-240). Arterial blood acid-base balance (pH, standard bicarbonate and base excess), gas tension (PaO2, PaCO2, SaO(2)) and electrolytes (Na+, K+, iCa(2+), Cl-) were recorded at T-0, T-30, T-60, T-120, T-180 and T-240. Ataxia was evaluated at T-0, T-30, T-60, T-120, T-180 and T-240 and at 1 hour intervals thereafter until analgesia was no longer present in each animal.Results Epidurally administered ropivacaine induced variable analgesia extending bilaterally from the coccyx to S3. Time to onset of analgesia and mean duration in the perineal area were 15 +/- 4 and 359 +/- 90 minutes, respectively. Respiratory rate and RT increased from T-120 to T-240 when compared to the value at T-0. Ionized calcium and chloride concentrations increased at T-180 and T-240 when compared to T-0. The other variables were not significantly different from baseline values (p > 0.05). Four animals were mildly ataxic.Conclusion and clinical relevance Ropivacaine (0.75%, 0.11 mg kg(-1)) can be administered by caudal epidural injection to produce prolonged bilateral perineal analgesia with minimal ataxia and cardiopulmonary changes in standing cattle.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND AND OBJECTIVES: The loss of resistance to air to identify the epidural space is widely used. However, the accidental perforation of the dura mater is one of the possible complications of this procedure, with an estimated incidence between 1% and 2%. The objective of this report was to describe the case of a patient with intraventricular pneumocephalus after the accidental perforation of the dura mater using the loss of resistance with air technique. CASE REPORT: Female patient, 26 years old, 75 kg, 1.67 m, physical status ASA I, with a 38-week pregnancy, was referred to the obstetric service for a cesarean section. Venipuncture was performed after placement of the monitoring. The patient was placed in a sitting position for administration of the epidural anesthesia. During the identification of the epidural space with the loss of resistance with air technique, an accidental perforation of the dura mater was diagnosed by observing free flow of CSF through the needle. The technique was modified to epidural anesthesia and anesthetics were administered by the needle placed in the subarachnoid space. In the first 24 hours, the patient developed headache and she was treated with caffeine, dypirone, hydration, hydrocortisone, and bed rest; despite those measures, the patient's symptoms worsened and evolved to headache in decubitus. A CT scan of the head showed the presence of pneumocephalus. After evaluation by a specialist, the patient remained under observation, with progressive improvement of the symptoms and was discharged from the hospital in the fifth day, without complications. CONCLUSIONS: Pneumocephalus after accidental perforation of the dura mater presented headache with the characteristics of headache secondary to loss of CSF, but with spontaneous resolution after the air was absorbed. Invasive measures, such as epidural blood patch, were not necessary. © Sociedade Brasileira de Anestesiologia, 2006.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Pós-graduação em Cirurgia Veterinária - FCAV